AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |
Back to Blog
Xbar meaning12/22/2023 ![]() This priority 2 syslog message is printed and accompanies a software power supply shutdown Detected power supply 1. If both power supplies are the same capacity or the mode is combined, software never shuts down a power supply. Software shuts down the lower capacity power supply only if it detects a mis-matched pair of power supplies and the mode is redundant or there is a transition from combined to redundant mode. Shutdown – Software has shutdown the power supply.Whenever a power supply fails, software prints this priority 2 syslog message Power supply 1 failed or shutdown (Serial number xxxx). Fail/Shutdown – Either the power supply has failed or it is shutdown using the switch on the power supply.Ok – Power supply is functioning properly.Total Power Available for additional modules 7215 W Total Power of all Inputs (cumulative) 12000 W Total Power Capacity (based on configured mode) 12000 W Power Supply redundancy mode (operational) Non-Redundant Power Supply redundancy mode (configured) PS-Redundant The command as well as a sample output is provided. This command displays the power supplies installed, power usage summary and status of power supplies on the switch. No explicit action is taken by software on a Power Supply fan failure, other than indicating such a failure using syslog messages.Fan module has been absent for 120 seconds" If software detects a removal, this priority 0 syslog message is printed every 5 seconds. The switch will be shutdown in 5 minutes. If the fan module is partially inserted or software is unable to access the SEEPROM on the fan module due to any other reason, software cannot distinguish this case from a real fan module removal. Software reads a byte on the Serial Electrically Erasable Programmable Read Only Memory (SEEPROM) to determine if the fan module is present. As soon as the fan module is removed, software starts a 5 minute countdown if the fan module is not re-inserted within 5 minutes, the entire switch is shutdown. This priority 1 syslog message is printed: Fan module Failed. If at least one fan has failed, this status is displayed. Software cannot determine if a single fan, multiple fans, or all fans have failed. Failure – One or more fans or fan controller have failed.Ok – All fans including the fan controller are functioning properly.SITE1-AGG1# show environment fanįan Zone Speed: Zone 1: 0x78 Zone 2: 0x58įan status can be one of ok, failure or absent. This command displays the fan module status on the switch.
0 Comments
Read More
Leave a Reply. |